24V AC 2 in 1 power and control signal surge protector for cctv system

 
Safety precautions:
a)   When the SPD box is installed in final system, it must achieve all the requirements of GB4943 (EN60950, IEC60950) standard;
b)   The equipment has to be installed by authorized professional person, before installation, to cut off power supply, and prohibit hot-line work from accidents  
 
Specification
Product model
AJ2B-24
1. power SPD specification
Max continuous working voltage (Uc)
24V AC
Nominal discharge current (In)
10KA
Max discharge current (In)
20KA
Protection level
≤100V
2. Control SPD specification
 
PTZ control
Max continuous working voltage (Uc)
12
Nominal discharge current (In)
5KA
Max discharge current (In)
10KA
Protection level
≤25V(core wire—case/ground)
Data transmission rate
≤100Mbps
Impedance
75Ω
Insertion loss
≤0.5dB
Interface type
2P terminal
3. other specification
Case
Aluminum material, oxidation surface(black, silver)
Dimension
110*61*28mm (including interface)
Wire interface
Power supply
Compression joint port, suitable for 16-26AWG(0.15-1.3mm²) wire
Control signal
Ground
Earth wire terminal or 2.5mm²earth wire
Installation
Inside of box or cabinet
Working conditions
Temperature:-40~+85℃; Relative humidity:≤95%(25℃); Elevation≤3km
 
Installation and wiring
1)  According to protection demands, the SPD is connected by series between protected devices and signal path, the closer the distance to protected devices, the better the protection effect.
2)  To connect separately a)the cable to the input terminal of power, video and control port, b) output terminal of SPD power, video and control to related interface of protected devices, c) ground line of SPD to earth wire of lightning protection system
3)  After wiring, please check it until everything is going well, to put into operation.
 
Product maintenance
1)  The product does not need to be maintained specially, but to inspect at fixed period, especially before and during thunderstorm season.
2)  Once there is a failure during system operation, please remove the SPD device at first, if the system can operate normally, the device is broken